With regard to X-ray structure analysis, the use of automated data-collection devices in conjunction with sophisticated software packages has, in the most part, eliminated the need for accurate crystal-setting techniques, although it should be remembered that the determination of the precise crystal orientation with respect to the instrument axes is a prerequisite for data processing. Furthermore, in the case of samples that are highly radiation sensitive (e.g. viruses), the lifetime of the sample in the X-ray beam does not permit accurate setting. However, the exercise of setting a crystal so that a certain morphological feature and/or unit-cell edge is perpendicular or parallel to the X-ray beam at the start of the experiment is often very useful, not only in establishing the quality of the crystal diffraction pattern (spot dimensions, mosaicity, twinning, limit of resolution, susceptibility to radiation damage, etc.), but also in ensuring that intensity data are collected in the most efficient manner and that the data set is as complete as possible (see also Subsection 3.4.2.8). Mounting a crystal specimen in a random orientation can often lead to inefficient data collection (some reflections measured several times and volumes of reciprocal space not measured at all), and in extreme cases can lead to inappropriate or incorrect choice of cell and space group. Optical examination, crystal density measurement, and careful analysis of diffraction data should still be regarded as important components of crystal structure analysis, even though data collection may be fully automated.
In most cases, the problem of crystal setting by X-rays is composed of two parts (Jeffery, 1971):
In the rotation or oscillation methods, the given direction is the camera rotation axis, but precession geometry requires a direct-lattice vector to be aligned along the X-ray beam. This section will briefly discuss:
Specialized methods for orientating and cutting large single crystals are not covered, but two-axis goniometers have been designed by Denne (1971a) and Shaham (1982
), and methods for cutting single crystals along any desired direction have been reported by Campos, Cardoso & Caticha-Ellis (1983
) and Desai & Bhatt (1984
).