Figure 6.2.2.3 

B. P. Schoenborna* and R. Knottb

a Life Sciences Division M888, University of California, Los Alamos National Laboratory, Los Alamos, NM 8745, USA, and bSmall Angle Scattering Facility, Australian Nuclear Science & Technology Organisation, Physics Division, PMB 1 Menai NSW 2234, Australia
Correspondence e-mail:  schoenborn@lanl.gov

[Figure 6.2.2.3]
Figure 6.2.2.3

Neutron flux given as a time–wavelength spectrum for (a) a fully decoupled system and (b) for a fully coupled system. Both spectra are based on Monte Carlo codes (LAHET and HMCNP) and are calculated for a target-to-sample distance of 10 m. Comparison of such Monte Carlo results calculated using the geometry of an existing beamline shows agreement with measured values to within 10%.