modify your search
 Results for DC.creator="G." AND DC.creator="Álvarez-Pinazo"   page 1 of 2 pages.
Accuracy in Rietveld quantitative phase analysis with strictly monochromatic Mo and Cu radiations
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, ch. 3.10, pp. 374-384 [ doi:10.1107/97809553602060000955 ]
... . 3.10.2.3. Crystalline organic series | | A constant matrix of glucose (G), fructose (F) and lactose (L) was prepared. Six samples with ... Table 3.10.3 shows RQPA results for six mixtures prepared with G, F, L and an increasing amount of X measured with ... wt% Mo trm Cu rfl wt% Mo trm Cu rfl G 33.4 33.8 (1) 33.5 (3) 33.3 33.6 (1) 33.1 ( ...

Increasing amorphous content series within an inorganic crystalline phase matrix
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.9, pp. 382-383 [ doi:10.1107/97809553602060000955 ]
... León-Reina, L., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A. G. & Aranda, M. A. G. (2016). Accuracy in Rietveld quantitative phase analysis: a ...

Increasing crystalline organic phase content series
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.8, pp. 381-382 [ doi:10.1107/97809553602060000955 ]
... Table 3.10.3 shows RQPA results for six mixtures prepared with G, F, L and an increasing amount of X measured with ... wt% Mo trm Cu rfl wt% Mo trm Cu rfl G 33.4 33.8 (1) 33.5 (3) 33.3 33.6 (1) 33.1 (2 ... wt% Mo trm Cu rfl wt% Mo trm Cu rfl G 33.0 34.7 (1) 33.6 (2) 32.7 32.2 (1) 31.5 ( ...

Increasing inorganic crystalline phase content series
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.7, p. 381 [ doi:10.1107/97809553602060000955 ]
... squares fits are also shown. References Cuesta, A., Álvarez-Pinazo, G., García-Maté, M., Santacruz, I., Aranda, M. A. G., De la Torre, Á. G. & León-Reina, L. (2015). Rietveld quantitative phase ...

Limits of detection and quantification
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.6, pp. 379-381 [ doi:10.1107/97809553602060000955 ]
... León-Reina, L., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A. G. & Aranda, M. A. G. (2016). Accuracy in Rietveld quantitative phase analysis: a ...

Crystalline single phases
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.5, pp. 377-379 [ doi:10.1107/97809553602060000955 ]
... León-Reina, L., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A. G. & Aranda, M. A. G. (2016). Accuracy in Rietveld quantitative phase analysis: a ...

Powder-diffraction data analysis
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.4, p. 377 [ doi:10.1107/97809553602060000955 ]
... previously (Madsen et al., 2011 ). References Aranda, M. A. G., De la Torre, Á. G. & León-Reina, L. (2012). Rietveld quantitative phase analysis ... Rev. Mineral. Geochem. 74, 169-209.GoogleScholar De La Torre, A. G., Bruque, S. & Aranda, M. A. G. (2001). Rietveld ...

Transmission synchrotron X-ray powder diffraction (SXRPD)
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.3.3, pp. 376-377 [ doi:10.1107/97809553602060000955 ]
Transmission synchrotron X-ray powder diffraction (SXRPD) 3.10.3.3. Transmission synchrotron X-ray powder diffraction (SXRPD) Powder patterns for the lowest analyte content samples, CGpQ_0.12A and GFL_0.12X, were also measured using synchrotron radiation. SXRPD data were collected in Debye-Scherrer (transmission) mode using the powder diffractometer at the ALBA Light ...
     [more results from section 3.10.3 in volume H]

Variable amorphous content series
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.2.4, pp. 375-376 [ doi:10.1107/97809553602060000955 ]
... I., Cuesta, A., León-Reina, L., Aranda, M. A. G., Baco, I., Morin, V., Walenta, G., Gartner, E. & De la Torre, A. G. (2014). Amorphous content determination in calcium sulfoaluminate related ...
     [more results from section 3.10.2 in volume H]

Introduction
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2018). Vol. H, Section 3.10.1, pp. 374-375 [ doi:10.1107/97809553602060000955 ]
... ray Diffraction Analysis. New York: Wiley.GoogleScholar Cuesta, A., Álvarez-Pinazo, G., García-Maté, M., Santacruz, I., Aranda, M. A. G., De la Torre, Á. G. & León-Reina, L. (2015). Rietveld quantitative phase ...

Page: 1 2 Next powered by swish-e
























































to end of page
to top of page