 Results for DC.creator="A." AND DC.creator="Cuesta" in section 3.10.3 of volume H
Transmission synchrotron X-ray powder diffraction (SXRPD)
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2019). Vol. H, Section 3.10.3.3, pp. 376-377 [ doi:10.1107/97809553602060000955 ]
... 2013 ). The wavelength, [lambda] = 0.77439(2)Å, was selected with a double-crystal Si(111) monochromator and was determined using the NIST SRM640d Si standard (a = 5.43123Å). The diffractometer is equipped with a MYTHEN-II detector system. The samples were loaded into ...

CuK[alpha]1 laboratory X-ray powder diffraction (LXRPD)
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2019). Vol. H, Section 3.10.3.2, p. 376 [ doi:10.1107/97809553602060000955 ]
... samples were recorded in reflection geometry ([theta]/2[theta]) on a X'Pert MPD PRO (PANalytical B.V.) diffractometer (240mm radius) equipped with a Ge(111) primary monochromator, which gives monochromatic Cu radiation ([lambda ... was operated at 45kV and 40mA. The optics configuration was a fixed divergence slit (0.5°), a fixed incident anti-scatter ...

MoK[alpha]1 laboratory X-ray powder diffraction (LXRPD)
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2019). Vol. H, Section 3.10.3.1, p. 376 [ doi:10.1107/97809553602060000955 ]
... order to avoid any correction of the measured intensities, on a D8 ADVANCE (Bruker AXS) diffractometer (188.5mm radius) equipped with a Ge(111) primary monochromator, which gives monochromatic Mo radiation ([lambda ... tube operated at 50kV and 50mA. The optics configuration was a fixed divergence slit (2°) and a fixed diffracted anti- ...

Analytical techniques
León-Reina, L., Cuesta, A., García-Maté, M., Álvarez-Pinazo, G., Santacruz, I., Vallcorba, O., De la Torre, A.G. and Aranda, M.A.G.  International Tables for Crystallography (2019). Vol. H, Section 3.10.3, pp. 376-377 [ doi:10.1107/97809553602060000955 ]
... coefficients for all of the phases, as microabsorption is always a concern in RQPA. A microabsorption correction was not applied in this work, but readers ... order to avoid any correction of the measured intensities, on a D8 ADVANCE (Bruker AXS) diffractometer (188.5mm radius) equipped with ...