Integrating detectors
Gruner, S. M., Eikenberry, E. F. and Tate, M. W.  International Tables for Crystallography (2012). Vol. F, Section 7.1.3.2.2, pp. 180-181 [ doi:10.1107/97809553602060000820 ]
... stable setup. Storage phosphors are typically read out with 100m square pixels, resulting in pixel images for the common size ... Instrum. Methods Phys. Res. A, 266, 645-653. Arndt, U. W. (1991). Second-generation X-ray television area detectors. Nucl. ... Instrum. Methods Phys. Res. A, 310, 395-397. Arndt, U. W., Gilmore, D. J. & Wonacott, A. J. (1977). X- ...

Photon-counting detectors
Gruner, S. M., Eikenberry, E. F. and Tate, M. W.  International Tables for Crystallography (2012). Vol. F, Section 7.1.3.2.1, pp. 179-180 [ doi:10.1107/97809553602060000820 ]
... these problems, two-dimensional gas-detector prototype modules with 200m square pixels have been constructed that are expected to have ... construction and characterization. Rev. Sci. Instrum. 60, 2315-2317. Blum, M., Metcalf, P., Harrison, S. C. & Wiley, D. C. (1987). ... 201, 181-192. Farrell, R., Vanderpuye, K., Cirignano, L., Squillante, M. R. & Entine, G. (1994). Radiation detection performance of ...

Counting and integrating detectors
Gruner, S. M., Eikenberry, E. F. and Tate, M. W.  International Tables for Crystallography (2012). Vol. F, Section 7.1.3.2, pp. 179-181 [ doi:10.1107/97809553602060000820 ]
... these problems, two-dimensional gas-detector prototype modules with 200m square pixels have been constructed that are expected to have ... stable setup. Storage phosphors are typically read out with 100m square pixels, resulting in pixel images for the common size ... Instrum. Methods Phys. Res. A, 266, 645-653. Arndt, U. W. (1991). Second-generation X-ray television area detectors. ...

Point versus linear versus area detection
Gruner, S. M., Eikenberry, E. F. and Tate, M. W.  International Tables for Crystallography (2012). Vol. F, Section 7.1.3.1, p. 179 [ doi:10.1107/97809553602060000820 ]
Point versus linear versus area detection 7.1.3.1. Point versus linear versus area detection A point detector may be based on a scintillating crystal or a gas-filled counter, with the sensitive area defined by slits or a pinhole mask. The spatial resolution of such a detector can be made arbitrarily fine ...

Characteristics of different detector approaches
Gruner, S. M., Eikenberry, E. F. and Tate, M. W.  International Tables for Crystallography (2012). Vol. F, Section 7.1.3, pp. 179-181 [ doi:10.1107/97809553602060000820 ]
... these problems, two-dimensional gas-detector prototype modules with 200m square pixels have been constructed that are expected to have ... stable setup. Storage phosphors are typically read out with 100m square pixels, resulting in pixel images for the common size ... Instrum. Methods Phys. Res. A, 266, 645-653. Arndt, U. W. (1991). Second-generation X-ray television area detectors. ...