modify your search
 Results for DC.creator="U." AND DC.creator="Das" in section 21.2.2 of volume F
Deviations from standard atomic volumes as a quality measure for protein crystal structures
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2.2.3, pp. 664-665 [ doi:10.1107/97809553602060000880 ]
Deviations from standard atomic volumes as a quality measure for protein crystal structures 21.2.2.2.3. Deviations from standard atomic volumes as a quality measure for protein crystal structures The observations that protein X-ray structures are at least as tightly packed as small-molecule crystals (Richards, 1974; Harpaz et al., 1994) and ...

Validation using knowledge-based interaction potentials and profiles
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2.2.2, pp. 663-664 [ doi:10.1107/97809553602060000880 ]
... based Z scores. References Eisenberg, D., Luthy, R. & Bowie, J. U. (1997). VERIFY3D: assessment of protein models with three-dimensional ...

Validation of stereochemical and non-bonded parameters
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2.2.1, p. 663 [ doi:10.1107/97809553602060000880 ]
Validation of stereochemical and non-bonded parameters 21.2.2.2.1. Validation of stereochemical and non-bonded parameters Morris et al. (1992) pioneered this type of validation for proteins. The software PROCHECK (Laskowski et al., 1993), which implements and extends this approach, is described in detail in Chapter 21.4 of this volume. A very ...

Comparisons against standard values derived from surveys of other macromolecules
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2.2, pp. 663-665 [ doi:10.1107/97809553602060000880 ]
... Libre de Bruxelles, Belgium. Eisenberg, D., Luthy, R. & Bowie, J. U. (1997). VERIFY3D: assessment of protein models with three-dimensional ...

Comparisons against standard values derived from crystals of small molecules
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2.1, pp. 662-663 [ doi:10.1107/97809553602060000880 ]
Comparisons against standard values derived from crystals of small molecules 21.2.2.1. Comparisons against standard values derived from crystals of small molecules This concerns the validation of the covalent geometry of the atomic model. It involves comparing the bond distances and angles of the macromolecule against standard values and their associated uncertainties ...

Validating the geometric and stereochemical parameters of the model
Wodak, S. J., Vagin, A. A., Richelle, J., Das, U., Pontius, J. and Berman, H. M.  International Tables for Crystallography (2012). Vol. F, Section 21.2.2, pp. 662-665 [ doi:10.1107/97809553602060000880 ]
... Cryst. 32, 125-133. Eisenberg, D., Luthy, R. & Bowie, J. U. (1997). VERIFY3D: assessment of protein models with three-dimensional ...

powered by swish-e
























































to end of page
to top of page