Powder dictionary (pdCIF) version 1.0.1
_pd_meas_2theta_range_
Names:'_pd_meas_2theta_range_min' '_pd_meas_2theta_range_max' '_pd_meas_2theta_range_inc'
Definition:
The range of 2\q diffraction angles in degrees for the measurement of intensities. These may be used in place of the _pd_meas_2theta_scan values for data sets measured with a constant step size.
The permitted range is -180.0 -> 360.0
Type: numb
Category: pd_meas_method