International
Tables for Crystallography Volume I X-ray absorption spectroscopy and related techniques Edited by C. T. Chantler, F. Boscherini and B. Bunker © International Union of Crystallography 2024 |
International Tables for Crystallography (2024). Vol. I. ch. 3.26, pp. 466-477
https://doi.org/10.1107/S157487072200324X Chapter 3.26. In situ and operando catalysis: instrumentation and experimental setupsaEuropean Synchrotron Radiation Facility (ESRF), 6 Rue Jules Horowitz, BP 220, 38043 Grenoble, France,bLeibniz Institute for Catalysis at the University of Rostock (LIKAT), Albert-Einstein-Strasse 29A, 18059 Rostock, Germany,cDiamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom,dDepartment of Chemistry, CrisDi Centre for Crystallography, University of Torino, Via Giuria 7, 10125 Torino, Italy, and eIRC `Smart Materials', Southern Federal University, 5 Zorge Street, Rostov-on-Don 344090, Russian Federation The instrumentation and experimental setups needed to investigate catalysts by X-ray absorption spectroscopy (XAS) under in situ and operando conditions are briefly described. The relevance of the simultaneous collection of XAS data while monitoring the activity and selectivity of the catalyst (operando setups) is stressed and the compromises that are necessary to construct an operando cell are discussed. The same approach is used for cells that allow additional simultaneous data collection (X-ray powder diffraction, small-angle X-ray scattering, infrared, Raman or UV–visible). The role of time-resolved and space-resolved experiments is discussed, together with the need for sophisticated software that is able to handle a huge amount of XAS spectra coupled with other independent data collections. Keywords: catalysis; ex situ; in situ; operando; reaction cells; time-resolved setups; space-resolved setups. |
The comprehension of and the correlation between catalytic performance, structure, electronic configuration and interaction of the catalyst, reactants and reaction intermediates are of paramount importance to improve the design of catalysts (Thomas, 1997). Due to the high dilution of the active species and the lack of long-range order typical of most catalysts, extended X-ray absorption fine structure (EXAFS) has been the technique of choice to understand the structure of the active sites, while the electronic configuration can be probed by X-ray absorption near-edge structure (XANES) and X-ray emission spectroscopy (XES) (Bordiga et al., 2013; Borfecchia et al., 2024; Boubnov et al., 2014; Günter et al., 2016; Lamberti & van Bokhoven, 2016).
To fulfil the need to operate under controlled temperature (T) and atmosphere, appropriate setups must be available at synchrotron-radiation beamlines. A typical setup for studying heterogeneous catalysts requires a cell where the catalyst, in a powdered or pelletized form, can be isolated from the external atmosphere. Such cells should allow both transmission and fluorescence detection (electron-yield detection is rarely used because of the poor electrical conductivity of most of the supports and the low mean free path of electrons in the presence of gases; Amakawa et al., 2013; Escudero et al., 2013; Hävecker et al., 2009; Kristiansen et al., 2013; Tamenori, 2013). In the case of experiments performed in transmission mode, the X-ray thickness of the sample must be optimizable, as for any XAS experiment. The cells must be compatible with accurate T and atmosphere control and allow the real-time study of catalyst activation and reactivity. A dynamic vacuum should be applicable to the cell and it should be capable of maintaining a static vacuum in the range 10−1–10−4 mbar (depending on the sensitivity of the catalyst to air) for the time period needed to perform the experiment (up to 4 h for EXAFS spectra collected in fluorescence mode from diluted samples and up to 8 h for resonant inelastic X-ray scattering map detection). We differentiate among ex situ, in situ and operando experiments.
In situ experiments involve measurements of the catalyst under well controlled and static conditions (T, pressure and chemical composition) to investigate the structure of the active sites before and after interaction with probe molecules (Lamberti et al., 2000; Valenzano et al., 2012) or after interaction with reactants (Borfecchia et al., 2015; Groppo et al., 2008; Leofanti et al., 2001, 2002; Muddada, Olsbye, Leofanti et al., 2010), i.e. showing the reactivity of the active sites towards reactants.
The experimental setup needed for operando experiments is more demanding (Beale et al., 2005; Boubnov et al., 2014; Doronkin et al., 2014; Ellis et al., 2010; Frenkel et al., 2012; Fulton et al., 2007; Gamarra et al., 2007, 2010; Hübner et al., 2011; Janssens et al., 2015; Kornienko et al., 2015; Lamberti et al., 2002; Lomachenko et al., 2016; Muddada, Olsbye, Caccialupi et al., 2010; Newton et al., 2016; Paolucci et al., 2016; Patlolla et al., 2012; Rabeah et al., 2016; Tada et al., 2007; Yao et al., 2014): gas-flow controllers are used to pass the desired gas feed with all of the reactants and the carrier gas needed for the reaction through the catalyst (for example C2H4, HCl and O2 for an oxychlorination reaction or NH3, NO and O2 for an ammonia selective catalytic reduction reaction). Operando experiments are performed in flux, where a fraction of the gas outlet from the cell is sampled and sent to a quadrupole mass spectrometer (MS) for simultaneous evaluation of the catalyst performance (activity and selectivity; Grunwaldt et al., 2005). The rapid response of MS analysis (1–20 s, depending on the number of sampled m/q ratios) is suited to time-resolved experiments, in which the catalyst temperature or the gas feed are changed. For steady-state experiments, MS should ideally be coupled to gas chromatography (GC), which guarantees a more accurate determination of the gas composition but requires longer times between two subsequent data collections, typically 10–20 min, which can be reduced to a few minutes with a micro-GC (Jian et al., 2012; Xu et al., 2016). Analysis of the gas outlet may also be performed by IR spectroscopy using appropriate gas cells. The use of toxic (CO, NO etc.), corrosive (NH3, HCl etc.) flammable (H2, C2H4, C2H2 etc.), oxidizing (O2, O3, NO2 etc.) or asphyxiating (N2, He etc.) gases requires particular care on chemical safety grounds. Ex situ experiments, which are used to analyze deactivated catalysts (Pellegrini et al., 2011), are less demanding in terms of experimental setup as neither T nor atmosphere control is required.
For absolute energy calibration in real time, which is particularly relevant in the quantitative analysis of XANES spectra in redox catalysts, a third ionization chamber is necessary to monitor the edge of a reference sample (usually the corresponding metal foil; Lamberti, Bordiga et al., 2003). This configuration is always possible for transmission setups, while in fluorescence setups it depends on the total absorption of the sample. When it is not possible to monitor the energy scale using a reference at the same time, the collection of a reference XANES spectrum before and after each catalytic experiment is highly recommended. Fig. 1 schematizes the typical experimental setup needed for XAS experiments in catalysis.
|
Typical setup for XAS experiments in catalysis. Adapted with permission from Bordiga et al. (2013). Copyright 2013 American Chemical Society. |
The next three sections describe the catalytic cells in more detail and underline the need to perform time-resolved and space-resolved experiments, reporting information on the corresponding setups and providing a list of beamlines where such instrumentation is available.
2. Cells allowing in situ and operando XAS and cells for simultaneous data collection with other vibrational (IR/Raman), electronic (UV–Vis, XES) or structural (SAXS, XRPD) techniques
Several authoritative reviews are available in the literature that describe cells for investigating catalysts under in situ and operando conditions using different spectroscopic and diffraction methods (Bare & Ressler, 2009; Bordiga et al., 2013; Doronkin et al., 2017; Grunwaldt et al., 2004; Meunier, 2010).
The most common way to prepare powdered samples (such as heterogeneous catalysts) for XAS data collection is to press the material into a cylindrical pellet with a thickness and concentration that are optimized to obtain the best signal in transmission. For this reason, many XAS cells for catalysis have been designed to control T and gas atmosphere/pressure around the pressed disk (Dent et al., 1992; Guilera et al., 2009; Lamberti, Prestipino et al., 2003; Sankar et al., 2007; Tibiletti et al., 2005; see Fig. 2a). This approach guarantees good homogeneity of the sample thickness, minimizing the consequences of minor movements of the beam on the sample during an EXAFS scan. The sample thickness can also be continuously tuned to optimize the signal-to-noise (S/N) ratio in the XAS spectra. This is the best solution for both in situ and ex situ experiments, but it is not ideal for operando experiments because the relatively low porosity of the pellet may suppress catalytic activity in the interior of the pellet. Also, reactant gases exiting the cell without interacting with the catalyst pellet may result in systematic errors in the evaluation of the catalyst activity/selectivity using MS and GC. This undesired effect can be minimized (but not eliminated) by designing cells with the smallest possible dead volume (i.e. the internal cell volume that is not occupied by the catalyst) and an optimized gas path. Such setups allow the collection of high-quality XAS data coupled with semi-quantitative catalytic data, and require standard catalytic tests to be repeated in the home laboratory for fully quantitative results. The alternative design reported in Fig. 2(b) forces the gas to diffuse through the entire cross section of a sample pellet (Meitzner et al., 1998). The drawback of this setup, which is also used for IR spectroscopy (Lesage et al., 2003), is that good porosity of the pellet is needed to minimize the pressure gap between the two sides of the cell. In some cases the porosity may be improved by mixing the catalyst with an inert phase that acts as a binder, such as alumina (γ-Al2O3), assuming that the catalytic properties of the sample are not altered (Doronkin et al., 2017) and that the overall sample homogeneity is not compromised.
For online collection of quantitative catalytic data, the XAS cell must mimic a real catalytic reactor and this constrains the cell design. The simplest catalytic reactor that is compatible with operando XAS data collection is a capillary containing the catalyst (Fig. 2c), where reagents can be flowed in and the temperature can be controlled using a heat gun (Clausen et al., 1991; Couves et al., 1991). Glass, quartz, Kapton or metal capillaries can be used depending on T, pressure conditions and the X-ray energy range that is required for the experiment. This setup requires care to prevent the catalyst powder being flushed away by the reactant stream. Usually, glass-wool bundles are inserted into the capillary before and after the catalyst powder to prevent this problem.
Often, to achieve reliable comprehension of the system under investigation it is essential to characterize the catalyst under working conditions using multiple techniques (Borfecchia et al., 2012; Jacques et al., 2009). This means that XAS experiments should be complemented by other techniques that provide vibrational and electronic results in addition to XAS structural information. A discussion of whether complementary techniques should be performed in separate experiments or simultaneously with XAS data collection has been provided elsewhere (Lamberti et al., 2016).
As discussed above, a cell for XAS measurements, and for spectroscopy in general, is not ideal for catalytic measurements because, besides optimizing the catalytic performance (the geometry of the catalytic bed and control of T and flow), it needs to allow the electromagnetic wave to probe the catalyst. Some of the difficulties that need to be overcome in cell design are feed impurities (for example an imperfectly sealed cell or degradation of the cell or some components), feed channelling and bed bypass, temperature gradients, X-ray beam effects, sample-preparation effects and catalytically active cell components etc. (Meunier, 2010). Other issues could arise from the necessity to control T in the catalytic bed, in particular for highly endothermic and exothermic reactions: Dilution of the sample with an inert and highly conductive solid is often not possible because it could decrease or alter the intensity of the spectroscopic signal. For instance, the optimal sample concentrations required for XAS and UV–Vis spectroscopy could be completely different and in some cases completely incompatible. The final point that we would like to highlight is the different volume and portion of the samples probed by each technique. This difference could be due to both the cell and the penetration depth of the different electromagnetic radiation inside the matter: for XAS it ranges up to millimetres, while for IR, for example, it only extends to a few hundred micrometres (Borfecchia et al., 2017).
The choice of a catalytic cell, and more generally of the entire experimental setup and the measurement configuration, suitable for the planned experiment will be driven by the scientific question. In planning an experiment, it will be necessary to clarify the priorities (time resolution, S/N ratio, temperature stability, combination of different techniques etc.), keeping in mind the advantages and drawbacks of each configuration (Grunwaldt et al., 2004). Without any ambition to be exhaustive, some issues are underlined in the following paragraphs. The best data quality with equal time resolution is obtained by working in transmission mode on self-supported pellets with a cell devoted to XAS measurements (for example, the setups reported in Figs. 2a and 2b). As the setup moves away from this configuration, for example using a capillary system (Fig. 2c) or the addition of a second spectroscopy (Fig. 2d), a poorer S/N ratio is obtained. On the other hand, the capillary setup is a plug flow reactor and is the best solution for kinetic experiments since the gas feed passes through the whole powder with an almost plane wave and no dead volume is present. The time resolution achievable will be driven, from the spectroscopic point of view, by the minimum S/N ratio that is acceptable to collect a spectrum that is able to provide useful information. Of course, other parameters such as sample–reactant contact time, concentration etc. will affect the kinetic reaction. Moreover, the combination of different techniques often requires some compromise. For example, combined XAS–X-ray power diffraction (XRPD) experiments need to be designed to find the best compromise for the X-ray path both for the scattering and absorption techniques. Combination of XAS with IR spectroscopy requires an IR-transparent window (Fig. 2d), with consequent heat loss from the sample surface. In this case, accurate measurement of the temperature at the sample surface is necessary and the possible presence of a temperature gradient along the catalytic bed must be considered.
Historically, the first operando XAS–XRPD experiment was performed by the Topsøe group, who measured the activity and selectivity of binary Cu–Zn and ternary Cu–Zn–Al catalysts during reduction and water–gas shift and methanol synthesis, allowing the understanding of both the short- and long-range order of the active phase (Clausen et al., 1991). Starting from this pioneering experimental setup, many variants were developed and produced (see, for example, Bordiga et al., 2013; Chupas et al., 2008; Figueroa et al., 2013; Frenkel et al., 2011; Meunier, 2010). The capillary system usually consists of a quartz capillary tube connected to a stainless-steel inlet and outlet by Swagelok tube fittings or glued directly to the tube. The outer diameter range is typically between 0.5 and 2 mm (to optimize μx and Δμx for the sample), with a wall thickness of 0.01 mm. Depending on the setup, the capillary reactor is heated by exposing it to a stream of hot gas (N2) produced by a heat gun (as represented in Fig. 2c) or by resistive wires placed close to the capillary. Temperature is controlled by a thermocouple within the capillary, located close to the catalyst, with a small diameter (below 0.2 mm) in order to minimize heat transfer without perturbing the gas flow. The capillary diameter, wall thickness and material can be varied according to the experimental requirements, in particular to work under high-pressure conditions where the thickness of the capillary walls needs to be increased. These setups are usually employed up to 1200 K and 20 bar (Figueroa et al., 2013).
An interesting approach is the solution adopted at the SNBL beamline of the ESRF (BM01B, subesquently moved to BM31). This facility is equipped with two independent Si(111) monochromators (channel cut for XRPD and double crystal for XAS) and is capable of switching in less than a minute from a scattering to an absorption setup on the same sample and vice versa, always with the optimized and calibrated energy for both experiments (Abdala et al., 2012; van Beek et al., 2011).
Combined XAS–XRPD measurements can be performed by mounting a diffractometer in Debye–Scherrer geometry with the capillary microreactor mounted horizontally (x axis) and the diffracted X-rays detected in the xz vertical plane (where y is the direction of incoming photons) (Bras et al., 2010). For XAS measurements, two ionization chambers are placed before and after the capillary to work in transmission geometry. If a fluorescence acquisition mode is needed, a solid-state detector is placed in the horizontal plane at 90° with respect to the direct beam (Fig. 1). In this case, in order to optimize the geometry configuration (to minimize the elastic beam and to maximize the solid angle between the catalyst and detector) the capillary system is rotated 45° with respect to incoming X-rays.
A further interesting development of the capillary setup for the investigation of the structure of catalysts under working conditions was performed on the BM26 beamline at ESRF (Beale et al., 2006; Nikitenko et al., 2008) using small-angle X-ray scattering (SAXS) techniques, probing large d-spacing, in addition to XAS and XRPD (also called WAXS). This setup is particularly suited to investigate samples during the synthesis process and is thus able to follow changes on scales ranging from nanometres to micrometres (Agostini et al., 2014; Groppo et al., 2012, 2014; Meneau et al., 2003).
For the complete characterization of a catalyst beyond the structural information provided by scattering techniques such as WAXS and SAXS, vibrational and electronic spectroscopies are very powerful when coupled with XAS in order to investigate the active sites, the reaction intermediates and the catalyst surface (Baier et al., 2015; Beale et al., 2005; Bordiga et al., 2015; Lamberti et al., 2010; Newton et al., 2004; Newton & van Beek, 2010). Two different types of cell will briefly be described in the following. The first type was originally developed by Beale and coworkers to combine Raman, UV–Vis and XAS in an energy-dispersive configuration (Beale et al., 2005). It is based on a quartz capillary. Raman and UV–Vis measurements can be carried out by irradiating and collecting the signal using a fibre optic, which can be inserted and placed in front of the catalyst quite easily. The use of a capillary reactor could give rise to issues derived from the round shape of the quartz reactor, which may alter the signal back-reflected to the probe. These problems can be overcome by making flat faces in the direction perpendicular to the incoming radiation, grinding a reactor tube (6 mm outer diameter and 1 mm inner diameter) made of optical grade quartz glass. The reactor is mounted in a square stainless-steel furnace and heated by four cartridges, with a maximum usable temperature of 920 K. The second type of cell is based on the idea of Evans and Newton to combine XAS with IR spectroscopy collected in diffuse reflectance (DR) mode (Newton et al., 2004). The cell is designed to be as close as possible to a plug flow reactor, with the sample in powder form and the gas feed passing through the catalytic bed. XAS measurements are performed in transmission geometry (which is compatible with both standard and energy-dispersive modes), while the IR spectrum is collected in DR geometry (Fig. 2d). A series of crucibles with different diameters to host the powder sample are available in order to be able to optimize the X-ray path as a function of the metal loading and the energy of XAS measurements in transmission mode (Fig. 2d, bottom). The cell is windowed with two carbon glass plates for X-rays and with a CaF2 crystal on top for IR. Recently, this cell was updated by the BM23/ID24 staff at the ESRF, maintaining the same geometrical configuration from IR spectroscopy but redesigning the whole cell to minimize the dead volume to 0.5 cm3, in order to measure both in transmission and fluorescence geometries and to work up to 970 K at a pressure of 10 bar (Fig. 2d).
Due to space limitations, this short review is focused on heterogeneous catalysts measured with hard X-rays. For the experimental setups used to investigate catalysts in the soft X-ray regime, we refer to Chen (1997), Hävecker et al. (2009), Somorjai et al. (2011) and Toyoshima & Kondoh (2015), while for homogeneous catalysis we just mention that stopped-flow cells (Gomez-Hens & Perez-Bendito, 1991; Inada et al., 1997) have been widely employed to investigate the time evolution of chemical reactions in the liquid phase by time-resolved XAS (Bartlett et al., 2011, 2014; Dent et al., 1999; Guilera et al., 2006; Oyanagi et al., 2011; Abdul Rahman et al., 2003; Smolentsev et al., 2009).
Timescales in homogeneous and heterogeneous catalysis range from milliseconds (nucleation and growth, sintering and particle morphology changes) to seconds (reaction-turnover times) to minutes (reduction and oxidation reactions) to hours or days (catalyst deactivation, degradation and ageing).
From its very earliest days, measuring a standard EXAFS spectrum in transmission mode has required about 1 h. With this standard setup, the spectrum was built up by collecting each data point at a fixed energy, with the monochromator stationary in angle (step-scan mode). When the desired collection time per point was reached, the monochromator was then moved to select the next energy and the measurement was repeated step by step until the whole energy range was covered. Whilst this is still a popular mode of data collection (and indeed produces accurate data in many cases), the overheads of moving and settling the monochromator make it difficult to follow a chemical reaction in real time. Indeed, for very low acquisition times per point, the scan time will be dominated by the dead time taken to move from one point to the next. More recently, technological advances have improved the time resolution to fractions of a second with `on-the-fly' or quick EXAFS (Q-EXAFS; Nachtegaal et al., 2016) and to milliseconds with energy-dispersive EXAFS (ED-XAS; Mathon et al., 2016), allowing the use of operando experiments under non-equilibrium conditions.
Q-EXAFS, or `on-the-fly XAS', removes the time overheads associated with step scanning by continuously moving a double-crystal or channel-cut monochromator through the energy range of interest at a constant speed, while the detectors and Bragg motor encoder are sampled simultaneously at regular time intervals that will define the energy resolution (step size). This mode was first introduced by Frahm at the RÖMO II beamline at HASYLAB (Frahm, 1988), and has now been implemented on many beamlines around the world such as, for example, BW1 (Richwin et al., 2001) at HASYLAB, SNBL (Abdala et al., 2012), BM29 (Prestipino et al., 2011), BM23 (Mathon et al., 2015) and DUBBLE (Nikitenko et al., 2008) at ESRF, B18 at Diamond Light Source (Dent et al., 2013), BL01 at SPring-8 (Tada et al., 2007), SuperXAS at SLS (Müller et al., 2016) etc. Dedicated Q-EXAFS systems have been implemented with technical details that allow subsecond resolution to be reached for a full EXAFS scan. This holds for a concentrated sample such as a metal foil, while on a catalytically relevant diluted sample a scan can routinely be acquired in a minute or less, or in a few seconds if the measurement is limited to only the XANES region.
The Q-EXAFS instrumentation, which allows high-performance time resolution, is characterized by a channel-cut crystal monochromator that moves in an oscillatory motion driven by an actuator with a frequency of up to 50 Hz around a preselected Bragg angle and by a data-acquisition system that simultaneously samples several detectors and encoders (Fig. 3a). This kind of monochromator has been installed on the SuperXAS beamline at the SLS (Müller et al., 2015), and other versions can be found on X18A and X18B (Khalid et al., 2011) at the NSLS (Brookhaven) and on BL33XU at Spring-8 (Uruga et al., 2007). The monochromator initially installed on the SAMBA beamline at the SOLEIL synchrotron (Fonda et al., 2012; see Fig. 3a) has since been moved to the ROCK (Briois et al., 2016) beamline at the same synchrotron and will be briefly commented on. A vertical motorized stage (left) performs the main rotation; this is necessary to align the oscillating crystal stage with an average Bragg angle. The oscillating stage produces the fast oscillation and controls its amplitude. The scheme on the right illustrates the working principle of the variable cam. A coupling system allows the transmission of a rotating motion through a flexure hinge to the monochromator crystals without mechanical play. This system allows frequencies of tens of hertz to be reached for scan collection. The drawback of Q-EXAFS monochromators is that they do not have a fixed exit, resulting in movement of the beam with respect to the sample during the energy scan. This means that a larger energy scan would result in a higher position shift of the X-ray beam on the sample, which is particularly relevant in the low-energy region (Ti, V and Cr K edges), where larger ΔθBragg are required for the same ΔE.
In the Q-EXAFS mode the data are still collected in a serial manner, which ultimately limits the speed. A completely different approach is energy-dispersive XAS or ED-XAS. The ED geometry (Pascarelli et al., 2016) uses a bent monochromator crystal (Allen et al., 1993; Hagelstein et al., 1995), where the variation of the diffraction angle over the crystal surface can be assumed to be linear. Depending on the illuminated length and Bragg angle a specific energy range is diffracted. The sample under investigation is located at the focal point of the monochromator (Fig. 3b), and the intensity of the different diffracted energies is measured by a position-sensitive detector (Oyanagi et al., 1986). At each channel of this detector an energy interval is then attributed following a careful calibration process (Ruffoni & Pettifer, 2006). Thus, one can take repeated snapshots of the entire EXAFS spectrum on a timescale of few microseconds, limited only by the detector readout time and the photon flux. On diluted samples, as relevant in catalysis, the actual time resolution is usually in the millisecond range.
Historically, the use of ED-XAS started almost 40 years ago at the II-4 beamline of SSRL, with a collaboration between scientists from Stanford and from the Photon Factory in Tsukuba (Kaminaga et al., 1981; Matsushita & Phizackerley, 1981; Phizackerley et al., 1983). Successively, this technique has spread to many other synchrotron sources, for example the Photon Factory in Japan (Saigo et al., 1986), the D11 beamline at the DCI storage ring of LURE (Dartyge et al., 1986; Flank et al., 1982, 1983), the DEXAFS station of the DESY storage ring in HASYLAB (Hagelstein et al., 1989), the SRS in Daresbury (Allinson et al., 1988; Dent et al., 1999), the EXAFS-PULS beamline at the ADONE synchrotron in Frascati (D'Acapito et al., 1992) and the X6A beamline at the NSLS (Lee et al., 1994). Several ED beamline are now available worldwide, among them ID24 at the ESRF (Pascarelli et al., 2016), I20 at Diamond Light Source (Diaz-Moreno et al., 2009), ODE at SOLEIL (Baudelet et al., 2011), D06A at LNLS (Cezar et al., 2010), BL08 at Indus-2 (Bhattacharyya et al., 2009), BL2.2 at SLRI (Poo-arporn et al., 2012) and the ED beamline of the Kurchatov Synchrotron Radiation Source in Moscow (Aksenov et al., 2006).
Despite this high time resolution, two main problems restrict the applications of ED-XAS. Firstly, spectral normalization and compensation with respect to I0 are an issue due to beam instability in flux and position and to homogeneity of samples. Secondly, the ED geometry is efficient in the transmission geometry configuration only. Both drawbacks can be partially overcome by scanning a narrow slit of few tens of micrometres through the polychromatic fan of radiation downstream of the crystal and selecting a monochromatic beam, the intensity of which is simultaneously recorded before and after the sample by two ionization chambers, while the fluorescence emitted by the sample is simultaneously collected by a standard multi-element solid-state detector (Pascarelli et al., 1999). The cost of this setup is that the time resolution is driven by the slit scan (typically hundreds of milliseconds). An ad hoc catalytic cell has been developed for this specific setup (Guilera et al., 2009) and some relevant results have been obtained (see, for example, Nagai et al., 2008).
For the time-resolved characterization of photocatalysis, ultrafast pump-and-probe spectroscopic methods are also relevant in order to probe photo-induced structural and electronic dynamics on timescales in the microsecond to picosecond range at third-generation synchrotrons, and potentially on the femtosecond scale at XFEL sources. These methods are based on the response to an external excitation (primarily laser pulses for photocatalysts, but also heat, magnetic field etc. for different systems) and the measurements are performed in differential mode by means of pump–probe schemes (Borfecchia et al., 2013; Bressler & Chergui, 2004, 2010; Chen, 2004; Milne et al., 2014; see Fig. 2c). Transient difference signals (between the excited and ground state) are recorded for each energy point and the spectrum is then built up; several repetitions are typically needed to improve the signal-to noise ratio. Different setups have been developed to monitor X-ray absorption, emission and scattering processes and to cover the whole temporal range (Chen et al., 2014).
To collect XAS on photo-active systems in the solution phase on the microsecond timescale, the pump–flow–probe method can be employed. Here, the liquid samples flow through a jet and the technique exploits the spatial separation between the spot where the two beams (laser excitation and X-ray probe) hit the sample, so that the time delay is defined by the speed of the liquid sample and the spatial separation between the two beam spots. A setup for pump–flow–probe measurements exists at the SuperXAS beamlines (Smolentsev et al., 2013). As opposed to pump–flow–probe methods, conventional pump–probe setups exploit the temporal structure of the X-ray beam at a synchrotron (top right corner of Fig. 3d), and the highest resolution (femtoseconds) can only be achieved at X-ray free-electron lasers or slicing sources at synchrotrons since it is limited by the duration of the X-ray pulse (bottom left corner of Fig. 3d). The time delay between the laser pump and X-ray probe can be tuned electronically by gating the detector or mechanically by chopping the X-ray beam (with the second method having the advantage of reducing the X-ray damage since the sample is only irradiated for the measurement). Laser pump–X-ray probe setups exploiting the temporal structure of the X-ray source (top right corner of Fig. 3d) have been developed at third-generation synchrotrons. Among the different available beamlines we mention 7-ID-D (March et al., 2011) and 11-ID-D (Chen et al., 2010; Jennings et al., 2002) at APS, Chicago, USA, MicroXAS (Lima et al., 2011) at SLS, Villigen, Switzerland, P11 (Britz et al., 2016; Göries et al., 2016) at PETRA III, Hamburg, Germany and NW14A (Sato et al., 2009) at the Photon Factory, Tsukuba, Japan. In recent years the new hard X-ray free-electron laser (FEL) sources have boosted the physics and chemistry of time-resolved experiments, providing ultrahigh fluxes of up to ∼1012 photons per pulse (compared with 106 photons per pulse at third-generation synchrotrons) and extreme short length (tens of femtoseconds, compared with hundreds of picoseconds). Pump-and-probe experiments at FELs can be performed at SACLA in Japan (Canton et al., 2015; Ishikawa et al., 2012), at the XPP endstation of the LCLS in Stanford (Cammarata et al., 2014; Harmand et al., 2013) and at the FXE endstation of the European XFEL, Hamburg, Germany.
In tandem with the temporal resolution, another important property of synchrotron-based techniques is the considerable spatial resolution that is achievable at these facilities (Martinez-Criado et al., 2013; Mino et al., 2018; Suzuki & Terada, 2016). The capability to focus the beam and map different points of the sample has been thoroughly exploited by X-ray fluorescence (Kalirai et al., 2015), imaging (Andrews & Weckhuysen, 2013; Aramburo et al., 2013) and tomography (Gonzalez-Jimenez et al., 2012; Grunwaldt & Schroer, 2010; Meirer, Kalirai, Weker et al., 2015), but it also has a relevant application in the case of the EXAFS technique, in particular when applied to catalysis studies, since it allows characterization of the axial structural variance of working catalysts along a reaction bed (Doronkin et al., 2014; Grunwaldt et al., 2013; Günter et al., 2016; Hannemann et al., 2007, 2009; Kimmerle et al., 2009). The absence or presence of such structural gradients is of considerable interest in the realistic application of heterogeneous catalysts and is not easily established in any other way. Certainly, the possibility of performing time-resolved and space-resolved measurements (Doronkin et al., 2014) is strictly connected to the development of in situ cells that allow reaction environments to be reproduced that are as close as possible to those that the catalysts would experience under actual working conditions. Several adjustments in terms of scale and materials are required to make the cell compatible with X-ray absorption measurements: thin windows of a material mainly composed of light elements (Kapton, Mylar, glassy carbon, mica etc.) to optimize transmission that is possibly not crystalline and with a negligible amount of impurities to minimize unwanted spurious diffraction or scattering or fluorescence signals that would introduce systematic artefacts into the measurement.
Capillary-like cells (Figs. 2c, 4a and 4b) offer ideal conditions in terms of gas/liquid flow, temperature range and pressure resistance, providing a great tool for an improved full structural characterization of catalysts, so many groups started to develop custom-built in situ cells based on plug flow capillary reactors (Bare et al., 2007; Fiddy et al., 1999; Newton et al., 2003). Moreover, the capillary provides a linear environment for gas/liquid flow and good accessibility to different points of the catalyst bed, allowing space-resolved measurements that are capable of discerning differences between the start and the end of the catalytic bed, where the gas/liquid composition can be very different depending on the rate of reactant consumption and product formation (Newton et al., 2016). If the temporal resolution for data acquisition is sufficiently higher than the reaction rate, it is also possible to monitor progress along the bed of the reaction front. A possibility is to loop on the different points of the catalytic bed (from 1 to n in Fig. 4a; Doronkin et al., 2014); alternatively, a full-field approach (Andrews & Weckhuysen, 2013; Grunwaldt & Schroer, 2010; Meirer, Morris et al., 2015) must be adopted.
A nanoreactor originally designed for environmental high-resolution transmission electron microscopy (TEM) was adapted for scanning transmission X-ray microscopy (STXM) on beamline 11.0.2 (Kilcoyne et al., 2003) of the ALS synchrotron at BNL operating in the soft X-ray region (see Fig. 4c). This setup has provided several very interesting results for understanding catalysts under working conditions; see, for example, de Smit et al. (2008). Beamline 37XU (Terada et al., 2011) at SPring-8 is an example of an STXM setup operating in the hard X-ray region that is widely employed by the catalysis community (Tada et al., 2011).
Finally, using microfocus X-ray fluorescence and X-ray diffraction computed tomography (μ-XRF-CT and μ-XRD-CT, respectively) in combination with XANES on a single particle of a catalyst it is possible to study the active state under standard operating conditions, demonstrating the ability of chemical computed tomography to image the nature and the spatial distribution of a single catalyst particle under reaction conditions (Cats et al., 2013; Liu et al., 2016; Meirer, Kalirai, Morris et al., 2015; Meirer, Morris et al., 2015; Price, Geraki et al., 2015; Price, Ignatyev et al., 2015).
In recent years, impressive achievements have been obtained in the development and adaptation of spectroscopic techniques for in situ and operando studies of processes under real and close-to-real reaction conditions. Synchrotron-based XAS has emerged as one of the most used methods for the study of active sites in catalytic materials (Bordiga et al., 2013). Excellent spatial, temporal and energy resolution and the relatively high penetration depth of hard X-rays make it a perfect tool to investigate systems under reaction conditions (gas atmosphere or pressure, sample temperature) and to probe catalytic processes during the reaction (Buurmans & Weckhuysen, 2012; Grunwaldt et al., 2004; Grunwaldt & Clausen, 2002; Newton et al., 2002). The huge amount of data obtained by time-resolved or space-resolved data collection (and using multi-technique experiments) has generated the need for a new generation of software allowing the simultaneous handing of a large number of spectra and their treatment with advanced chemometric approaches such as principal component analysis (Cotte et al., 2016; Figueroa & Prestipino, 2016; Liu et al., 2012). When additional techniques (MS, GC, XRPD, SAXS, IR, Raman, UV–Vis etc.) are coupled with XES or XAS acquisitions, we foresee the need to drive all data collections with a single computer to allow perfect timing among the different data sets.
Acknowledgements
CL thanks the Russian Ministry of Education and Science for support (megagrant No. 14.Y26.31.0001). The authors are indebted to Elisa Borfecchia (Haldor Topsøe A/S, Denmark) for critical reading of the manuscript.
References
Abdala, P. M., Safonova, O. V., Wiker, G., van Beek, W., Emerich, H., van Bokhoven, J. A., Sá, J., Szlachetko, J. & Nachtegaal, M. (2012). Chimia, 66, 699–705.Google ScholarAbdul Rahman, M. B. B., Bolton, P. R., Evans, J., Dent, A. J., Harvey, I. & Diaz-Moreno, S. (2003). Faraday Discuss. 122, 211–222.Google Scholar
Agostini, G., Lamberti, C., Pellegrini, R., Leofanti, G., Giannici, F., Longo, A. & Groppo, E. (2014). ACS Catal. 4, 187–194.Google Scholar
Aksenov, V. L., Koval'chuk, M. V., Kuz'min, A. Y., Purans, Y. & Tyutyunnikov, S. I. (2006). Crystallogr. Rep. 51, 908–935.Google Scholar
Allen, P. G., Conradson, S. D. & Penner-Hahn, J. E. (1993). J. Appl. Cryst. 26, 172–179.Google Scholar
Allinson, N. M., Baker, G., Greaves, G. N. & Nicoll, J. K. (1988). Nucl. Instrum. Methods Phys. Res. A, 266, 592–597.Google Scholar
Amakawa, K., Sun, L. L., Guo, C. S., Hävecker, M., Kube, P., Wachs, I. E., Lwin, S., Frenkel, A. I., Patlolla, A., Hermann, K., Schlögl, R. & Trunschke, A. (2013). Angew. Chem. Int. Ed. 52, 13553–13557.Google Scholar
Andrews, J. C. & Weckhuysen, B. M. (2013). ChemPhysChem, 14, 3655–3666.Google Scholar
Aramburo, L. R., Liu, Y. J., Tyliszczak, T., de Groot, F. M. F., Andrews, J. C. & Weckhuysen, B. M. (2013). ChemPhysChem, 14, 496–499.Google Scholar
Baier, S., Rochet, A., Hofmann, G., Kraut, M. & Grunwaldt, J. D. (2015). Rev. Sci. Instrum. 86, 065101.Google Scholar
Bare, S. R. & Ressler, T. (2009). Adv. Catal. 52, 339–465.Google Scholar
Bare, S. R., Yang, N., Kelly, S. D., Mickelson, G. E. & Modica, F. S. (2007). Catal. Today, 126, 18–26.Google Scholar
Bartlett, S. A., Moulin, J., Tromp, M., Reid, G., Dent, A. J., Cibin, G., McGuinness, D. S. & Evans, J. (2014). ACS Catal. 4, 4201–4204.Google Scholar
Bartlett, S. A., Wells, P. P., Nachtegaal, M., Dent, A. J., Cibin, G., Reid, G., Evans, J. & Tromp, M. (2011). J. Catal. 284, 247–258.Google Scholar
Baudelet, F., Kong, Q., Nataf, L., Cafun, J. D., Congeduti, A., Monza, A., Chagnot, S. & Itié, J.-P. (2011). High Press. Res. 31, 136–139.Google Scholar
Beale, A. M., van der Eerden, A. M. J., Jacques, S. D. M., Leynaud, O., O'Brien, M. G., Meneau, F., Nikitenko, S., Bras, W. & Weckhuysen, B. M. (2006). J. Am. Chem. Soc. 128, 12386–12387.Google Scholar
Beale, A. M., van der Eerden, A. M. J., Kervinen, K., Newton, M. A. & Weckhuysen, B. M. (2005). Chem. Commun. 2005, 3015–3017.Google Scholar
Beek, W. van, Safonova, O. V., Wiker, G. & Emerich, H. (2011). Phase Transit. 84, 726–732.Google Scholar
Bhattacharyya, D., Poswal, A. K., Jha, S. N., Sangeeta & Sabharwal, S. C. (2009). Nucl. Instrum. Methods Phys. Res. A, 609, 286–293.Google Scholar
Bordiga, S., Groppo, E., Agostini, G., van Bokhoven, J. A. & Lamberti, C. (2013). Chem. Rev. 113, 1736–1850.Google Scholar
Bordiga, S., Lamberti, C., Bonino, F., Travert, A. & Thibault-Starzyk, F. (2015). Chem. Soc. Rev. 44, 7262–7341.Google Scholar
Borfecchia, E., Garino, C., Salassa, L. & Lamberti, C. (2013). Phil. Trans. R. Soc. A, 371, 20120132.Google Scholar
Borfecchia, E., Groppo, E., Bordiga, S. & Lamberti, C. (2024). Int. Tables Crystallogr. I, ch. 8.10, 988–998 .Google Scholar
Borfecchia, E., Lomachenko, K. A., Giordanino, F., Falsig, H., Beato, P., Soldatov, A. V., Bordiga, S. & Lamberti, C. (2015). Chem. Sci. 6, 548–563.Google Scholar
Borfecchia, E., Maurelli, S., Gianolio, D., Groppo, E., Chiesa, M., Bonino, F. & Lamberti, C. (2012). J. Phys. Chem. C, 116, 19839–19850.Google Scholar
Borfecchia, E., Mino, L., Groppo, E., Bordiga, S., Bugaev, A. L., Budnyk, A., Lomachenko, K. A., Guda, A. A., Soldatov, M. A., Soldatov, A. V. & Lamberti, C. (2017). Morphological, Compositional, and Shape Control of Materials for Catalysis, edited by P. Fornasiero & M. Cargnello, pp. 221–284. Amsterdam: Elsevier.Google Scholar
Boubnov, A., Carvalho, H. W. P., Doronkin, D. E., Günter, T., Gallo, E., Atkins, A. J., Jacob, C. R. & Grunwaldt, J. D. (2014). J. Am. Chem. Soc. 136, 13006–13015.Google Scholar
Bras, W., Nikitenko, S., Portale, G., Beale, A., Eerden, A. & Detollenaere, D. (2010). J. Phys. Conf. Ser. 247, 012047.Google Scholar
Bressler, C. & Chergui, M. (2004). Chem. Rev. 104, 1781–1812.Google Scholar
Bressler, C. & Chergui, M. (2010). Annu. Rev. Phys. Chem. 61, 263–282.Google Scholar
Briois, V., La Fontaine, C., Belin, S., Barthe, L., Moreno, T., Pinty, V., Carcy, A., Girardot, R. & Fonda, E. (2016). J. Phys. Conf. Ser. 712, 012149.Google Scholar
Britz, A., Assefa, T. A., Galler, A., Gawelda, W., Diez, M., Zalden, P., Khakhulin, D., Fernandes, B., Gessler, P., Sotoudi Namin, H., Beckmann, A., Harder, M., Yavaş, H. & Bressler, C. (2016). J. Synchrotron Rad. 23, 1409–1423.Google Scholar
Buurmans, I. L. C. & Weckhuysen, B. M. (2012). Nat. Chem. 4, 873–886.Google Scholar
Cammarata, M., Bertoni, R., Lorenc, M., Cailleau, H., Di Matteo, S., Mauriac, C., Matar, S. F., Lemke, H., Chollet, M., Ravy, S., Laulhé, C., Létard, J. F. & Collet, E. (2014). Phys. Rev. Lett. 113, 227402.Google Scholar
Canton, S. E., Kjaer, K. S., Vankó, G., van Driel, T. B., Adachi, S. I., Bordage, A., Bressler, C., Chabera, P., Christensen, M., Dohn, A. O., Galler, A., Gawelda, W., Gosztola, D., Haldrup, K., Harlang, T., Liu, Y. Z., Møller, K. B., Németh, Z., Nozawa, S., Pápai, M., Sato, T., Sato, T., Suarez-Alcantara, K., Togashi, T., Tono, K., Uhlig, J., Vithanage, D. A., Wärnmark, K., Yabashi, M., Zhang, J. X., Sundström, V. & Nielsen, M. M. (2015). Nat. Commun. 6, 6359.Google Scholar
Cats, K. H., Gonzalez-Jimenez, I. D., Liu, Y. J., Nelson, J., van Campen, D., Meirer, F., van der Eerden, A. M. J., de Groot, F. M. F., Andrews, J. C. & Weckhuysen, B. M. (2013). Chem. Commun. 49, 4622–4624.Google Scholar
Cezar, J. C., Souza-Neto, N. M., Piamonteze, C., Tamura, E., Garcia, F., Carvalho, E. J., Neueschwander, R. T., Ramos, A. Y., Tolentino, H. C. N., Caneiro, A., Massa, N. E., Martinez-Lope, M. J., Alonso, J. A. & Itié, J.-P. (2010). J. Synchrotron Rad. 17, 93–102.Google Scholar
Chen, J. G. (1997). Surf. Sci. Rep. 30, 1–152.Google Scholar
Chen, L. X. (2004). Angew. Chem. Int. Ed. 43, 2886–2905.Google Scholar
Chen, L. X., Zhang, X. & Shelby, M. L. (2014). Chem. Sci. 5, 4136–4152.Google Scholar
Chen, L. X., Zhang, X., Lockard, J. V., Stickrath, A. B., Attenkofer, K., Jennings, G. & Liu, D.-J. (2010). Acta Cryst. A66, 240–251.Google Scholar
Chupas, P. J., Chapman, K. W., Kurtz, C., Hanson, J. C., Lee, P. L. & Grey, C. P. (2008). J. Appl. Cryst. 41, 822–824.Google Scholar
Clausen, B. S., Steffensen, G., Fabius, B., Villadsen, J., Feidenhans'l, R. & Topsøe, H. (1991). J. Catal. 132, 524–535.Google Scholar
Cotte, M., Fabris, T., Agostini, G., Motta Meira, D., De Viguerie, L. & Solé, V. A. (2016). Anal. Chem. 88, 6154–6160.Google Scholar
Couves, J. W., Thomas, J. M., Waller, D., Jones, R. H., Dent, A. J., Derbyshire, G. E. & Greaves, G. N. (1991). Nature, 354, 465–468.Google Scholar
D'Acapito, F., Boscherini, F., Marcelli, A. & Mobilio, S. (1992). Rev. Sci. Instrum. 63, 899–901.Google Scholar
Dartyge, E., Depautex, C., Dubuisson, J. M., Fontaine, A., Jucha, A., Leboucher, P. & Tourillon, G. (1986). Nucl. Instrum. Methods Phys. Res. A, 246, 452–460.Google Scholar
Dent, A., Evans, J., Newton, M., Corker, J., Russell, A., Abdul Rahman, M. B., Fiddy, S., Mathew, R., Farrow, R., Salvini, G. & Atkinson, P. (1999). J. Synchrotron Rad. 6, 381–383.Google Scholar
Dent, A. J., Cibin, G., Ramos, S., Parry, S. A., Gianolio, D., Smith, A. D., Scott, S. M., Varandas, L., Patel, S., Pearson, M. R., Hudson, L., Krumpa, N. A., Marsch, A. S. & Robbins, P. E. (2013). J. Phys. Conf. Ser. 430, 012023.Google Scholar
Dent, A. J., Wells, M. P., Farrow, R. C., Ramsdale, C. A., Derbyshire, G. E., Greaves, G. N., Couves, J. W. & Thomas, J. M. (1992). Rev. Sci. Instrum. 63, 903–906.Google Scholar
Diaz-Moreno, S., Hayama, S., Amboage, M., Freeman, A., Sutter, J. & Duller, G. (2009). J. Phys. Conf. Ser. 190, 012038.Google Scholar
Doronkin, D. E., Casapu, M., Günter, T., Müller, O., Frahm, R. & Grunwaldt, J. D. (2014). J. Phys. Chem. C, 118, 10204–10212.Google Scholar
Doronkin, D. E., Lichtenberg, H. & Grunwaldt, J.-D. (2017). XAFS Techniques for Catalysts, Nanomaterials, and Surfaces, edited by Y. Iwasawa, K. Asakura & M. Tada, pp. 75–89. Cham: Springer.Google Scholar
Ellis, P. J., Fairlamb, I. J. S., Hackett, S. F. J., Wilson, K. & Lee, A. F. (2010). Angew. Chem. Int. Ed. 49, 1820–1824.Google Scholar
Escudero, C., Jiang, P., Pach, E., Borondics, F., West, M. W., Tuxen, A., Chintapalli, M., Carenco, S., Guo, J. & Salmeron, M. (2013). J. Synchrotron Rad. 20, 504–508.Google Scholar
Fiddy, S. G., Newton, M. A., Corker, J. M., Turin, S., Campbell, T., Evans, J., Dent, A. J. & Salvini, G. (1999). Chem. Commun. 1999, 851–852.Google Scholar
Figueroa, S. J. A., Gibson, D., Mairs, T., Pasternak, S., Newton, M. A., Di Michiel, M., Andrieux, J., Christoforidis, K. C., Iglesias-Juez, A., Fernández-García, M. & Prestipino, C. (2013). J. Appl. Cryst. 46, 1523–1527.Google Scholar
Figueroa, S. J. A. & Prestipino, C. (2016). J. Phys. Conf. Ser. 712, 012012.Google Scholar
Flank, A. M., Fontaine, A., Jucha, A., Lemonnier, M., Raoux, D. & Williams, C. (1983). Nucl. Instrum. Methods Phys. Res. 208, 651–654.Google Scholar
Flank, A. M., Fontaine, A., Jucha, A., Lemonnier, M. & Williams, C. (1982). J. Phys. Lett. 43, 315–319.Google Scholar
Fonda, E., Rochet, A., Ribbens, M., Barthe, L., Belin, S. & Briois, V. (2012). J. Synchrotron Rad. 19, 417–424.Google Scholar
Frahm, R. (1988). Nucl. Instrum. Methods Phys. Res. A, 270, 578–581.Google Scholar
Frenkel, A. I., Rodriguez, J. A. & Chen, J. G. G. (2012). ACS Catal. 2, 2269–2280.Google Scholar
Frenkel, A. I., Wang, Q., Marinkovic, N., Chen, J. G., Barrio, L., Si, R., Cámara, A. L., Estrella, A. M., Rodriguez, J. A. & Hanson, J. C. (2011). J. Phys. Chem. C, 115, 17884–17890.Google Scholar
Fulton, J. L., Linehan, J. C., Autrey, T., Balasubramanian, M., Chen, Y. & Szymczak, N. K. (2007). J. Am. Chem. Soc. 129, 11936–11949.Google Scholar
Gamarra, D., Belver, C., Fernández-García, M. & Martínez-Arias, A. (2007). J. Am. Chem. Soc. 129, 12064–12065.Google Scholar
Gamarra, D., Fernández-García, M., Belver, C. & Martínez-Arias, A. (2010). J. Phys. Chem. C, 114, 18576–18582.Google Scholar
Gomez-Hens, A. & Perez-Bendito, D. (1991). Anal. Chim. Acta, 242, 147–177.Google Scholar
Gonzalez-Jimenez, I. D., Cats, K., Davidian, T., Ruitenbeek, M., Meirer, F., Liu, Y. J., Nelson, J., Andrews, J. C., Pianetta, P., de Groot, F. M. F. & Weckhuysen, B. M. (2012). Angew. Chem. Int. Ed. 51, 11986–11990.Google Scholar
Göries, D., Dicke, B., Roedig, P., Stübe, N., Meyer, J., Galler, A., Gawelda, W., Britz, A., Gessler, P., Sotoudi Namin, H., Beckmann, A., Schlie, M., Warmer, M., Naumova, M., Bressler, C., Rübhausen, M., Weckert, E. & Meents, A. (2016). Rev. Sci. Instrum. 87, 053116.Google Scholar
Groppo, E., Agostini, G., Borfecchia, E., Wei, L., Giannici, F., Portale, G., Longo, A. & Lamberti, C. (2014). J. Phys. Chem. C, 118, 8406–8415.Google Scholar
Groppo, E., Agostini, G., Piovano, A., Muddada, N. B., Leofanti, G., Pellegrini, R., Portale, G., Longo, A. & Lamberti, C. (2012). J. Catal. 287, 44–54.Google Scholar
Groppo, E., Uddin, M. J., Bordiga, S., Zecchina, A. & Lamberti, C. (2008). Angew. Chem. Int. Ed. 47, 9269–9273.Google Scholar
Grunwaldt, J.-D., Caravati, M., Hannemann, S. & Baiker, A. (2004). Phys. Chem. Chem. Phys. 6, 3037–3047.Google Scholar
Grunwaldt, J.-D. & Clausen, B. S. (2002). Top. Catal. 18, 37–43.Google Scholar
Grunwaldt, J.-D., Hannemann, S., Gttlicher, J., Mangold, S., Denecke, M. A. & Baiker, A. (2005). Phys. Scr. 2005, 769.Google Scholar
Grunwaldt, J.-D. & Schroer, C. G. (2010). Chem. Soc. Rev. 39, 4741–4753.Google Scholar
Grunwaldt, J.-D., Wagner, J. B. & Dunin-Borkowski, R. E. (2013). ChemCatChem, 5, 62–80.Google Scholar
Guilera, G., Gorges, B., Pascarelli, S., Vitoux, H., Newton, M. A., Prestipino, C., Nagai, Y. & Hara, N. (2009). J. Synchrotron Rad. 16, 628–634.Google Scholar
Guilera, G., Newton, M. A., Polli, C., Pascarelli, S., Guino, M. & Hii, K. K. (2006). Chem. Commun. 2006, 4306–4308.Google Scholar
Günter, T., Doronkin, D. E., Boubnov, A., Carvalho, H. W. P., Casapu, M. & Grunwaldt, J. D. (2016). Top. Catal. 59, 866–874.Google Scholar
Hagelstein, M., Cunis, S., Frahm, R., Niemann, W. & Rabe, P. (1989). Physica B, 158, 324–325.Google Scholar
Hagelstein, M., Ferrero, C., Hatje, U., Ressler, T. & Metz, W. (1995). J. Synchrotron Rad. 2, 174–180.Google Scholar
Hannemann, S., Grunwaldt, J. D., Kimmerle, B., Baiker, A., Boye, P. & Schroer, C. (2009). Top. Catal. 52, 1360–1370.Google Scholar
Hannemann, S., Grunwaldt, J. D., van Vegten, N., Baiker, A., Boye, P. & Schroer, C. G. (2007). Catal. Today, 126, 54–63.Google Scholar
Harmand, M., Coffee, R., Bionta, M. R., Chollet, M., French, D., Zhu, D., Fritz, D. M., Lemke, H. T., Medvedev, N., Ziaja, B., Toleikis, S. & Cammarata, M. (2013). Nat. Photon. 7, 215–218.Google Scholar
Hävecker, M., Cavalleri, M., Herbert, R., Follath, R., Knop-Gericke, A., Hess, C., Hermann, K. & Schlögl, R. (2009). Phys. Status Solidi B, 246, 1459–1469.Google Scholar
Hübner, M., Koziej, D., Bauer, M., Barsan, N., Kvashnina, K., Rossell, M. D., Weimar, U. & Grunwaldt, J. D. (2011). Angew. Chem. Int. Ed. 50, 2841–2844.Google Scholar
Inada, Y., Hayashi, H., Funahashi, S. & Nomura, M. (1997). Rev. Sci. Instrum. 68, 2973–2977.Google Scholar
Ishikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., Goto, S., Hanaki, H., Hara, T., Hasegawa, T., Hatsui, T., Higashiya, A., Hirono, T., Hosoda, N., Ishii, M., Inagaki, T., Inubushi, Y., Itoga, T., Joti, Y., Kago, M., Kameshima, T., Kimura, H., Kirihara, Y., Kiyomichi, A., Kobayashi, T., Kondo, C., Kudo, T., Maesaka, H., Maréchal, X. M., Masuda, T., Matsubara, S., Matsumoto, T., Matsushita, T., Matsui, S., Nagasono, M., Nariyama, N., Ohashi, H., Ohata, T., Ohshima, T., Ono, S., Otake, Y., Saji, C., Sakurai, T., Sato, T., Sawada, K., Seike, T., Shirasawa, K., Sugimoto, T., Suzuki, S., Takahashi, S., Takebe, H., Takeshita, K., Tamasaku, K., Tanaka, H., Tanaka, R., Tanaka, T., Togashi, T., Togawa, K., Tokuhisa, A., Tomizawa, H., Tono, K., Wu, S., Yabashi, M., Yamaga, M., Yamashita, A., Yanagida, K., Zhang, C., Shintake, T., Kitamura, H. & Kumagai, N. (2012). Nat. Photon. 6, 540–544.Google Scholar
Jacques, S. D. M., Leynaud, O., Strusevich, D., Stukas, P., Barnes, P., Sankar, G., Sheehy, M., O'Brien, M. G., Iglesias-Juez, A. & Beale, A. M. (2009). Catal. Today, 145, 204–212.Google Scholar
Janssens, T. V. W., Falsig, H., Lundegaard, L. F., Vennestrøm, P. N. R., Rasmussen, S. B., Moses, P. G., Giordanino, F., Borfecchia, E., Lomachenko, K. A., Lamberti, C., Bordiga, S., Godiksen, A., Mossin, S. & Beato, P. (2015). ACS Catal. 5, 2832–2845.Google Scholar
Jennings, G., Jäger, W. J. H. & Chen, L. X. (2002). Rev. Sci. Instrum. 73, 362–368.Google Scholar
Jian, R. S., Huang, R. X. & Lu, C. J. (2012). Talanta, 88, 160–167.Google Scholar
Kalirai, S., Boesenberg, U., Falkenberg, G., Meirer, F. & Weckhuysen, B. M. (2015). ChemCatChem, 7, 3674–3682.Google Scholar
Kaminaga, U., Matsushita, T. & Kohra, K. (1981). Jpn. J. Appl. Phys. 20, L355–L358.Google Scholar
Khalid, S., Ehrlich, S. N., Lenhard, A. & Clay, B. (2011). Nucl. Instrum. Methods Phys. Res. A, 649, 64–66.Google Scholar
Kilcoyne, A. L. D., Tyliszczak, T., Steele, W. F., Fakra, S., Hitchcock, P., Franck, K., Anderson, E., Harteneck, B., Rightor, E. G., Mitchell, G. E., Hitchcock, A. P., Yang, L., Warwick, T. & Ade, H. (2003). J. Synchrotron Rad. 10, 125–136.Google Scholar
Kimmerle, B., Grunwaldt, J. D., Baiker, A., Glatzel, P., Boye, P., Stephan, S. & Schroer, C. G. (2009). J. Phys. Chem. C, 113, 3037–3040.Google Scholar
Kornienko, N., Resasco, J., Becknell, N., Jiang, C. M., Liu, Y. S., Nie, K. Q., Sun, X. H., Guo, J. H., Leone, S. R. & Yang, P. D. (2015). J. Am. Chem. Soc. 137, 7448–7455.Google Scholar
Kristiansen, P. T., Rocha, T. C. R., Knop-Gericke, A., Guo, J. H. & Duda, L. C. (2013). Rev. Sci. Instrum. 84, 113107.Google Scholar
Lamberti, C., Bordiga, S., Bonino, F., Prestipino, C., Berlier, G., Capello, L., D'Acapito, F., Llabrés i Xamena, F. X. & Zecchina, A. (2003). Phys. Chem. Chem. Phys. 5, 4502–4509.Google Scholar
Lamberti, C., Borfecchia, E., van Bokhoven, J. A. & Fernández-García, M. (2016). X-ray Absorption and X-ray Emission Spectroscopy: Theory and Applications, edited by J. A. van Bokhoven & C. Lamberti, pp. 303–350. Chichester: John Wiley & Sons.Google Scholar
Lamberti, C., Prestipino, C., Bonino, F., Capello, L., Bordiga, S., Spoto, G., Zecchina, A., Diaz Moreno, S., Cremaschi, B., Garilli, M., Marsella, A., Carmello, D., Vidotto, S. & Leofanti, G. (2002). Angew. Chem. Int. Ed. 41, 2341–2344.Google Scholar
Lamberti, C., Prestipino, C., Bordiga, S., Berlier, G., Spoto, G., Zecchina, A., Laloni, A., La Manna, F., D'Anca, F., Felici, R., D'Acapito, F. & Roy, P. (2003). Nucl. Instrum. Methods Phys. Res. B, 200, 196–201.Google Scholar
Lamberti, C., Turnes Palomino, G., Bordiga, S., Berlier, G., D'Acapito, F. & Zecchina, A. (2000). Angew. Chem. Int. Ed. 39, 2138–2141.Google Scholar
Lamberti, C. & van Bokhoven, J. A. (2016). X-ray Absorption and X-ray Emission Spectroscopy: Theory and Applications, edited by J. A. van Bokhoven & C. Lamberti, pp. 353–383. Chichester: John Wiley & Sons.Google Scholar
Lamberti, C., Zecchina, A., Groppo, E. & Bordiga, S. (2010). Chem. Soc. Rev. 39, 4951–5001.Google Scholar
Lee, P. L., Beno, M. A., Jennings, G., Ramanathan, M., Knapp, G. S., Huang, K., Bai, J. & Montano, P. A. (1994). Rev. Sci. Instrum. 65, 1–6.Google Scholar
Leofanti, G., Marsella, A., Cremaschi, B., Garilli, M., Zecchina, A., Spoto, G., Bordiga, S., Fisicaro, P., Berlier, G., Prestipino, C., Casali, G. & Lamberti, C. (2001). J. Catal. 202, 279–295.Google Scholar
Leofanti, G., Marsella, A., Cremaschi, B., Garilli, M., Zecchina, A., Spoto, G., Bordiga, S., Fisicaro, P., Prestipino, C., Villain, F. & Lamberti, C. (2002). J. Catal. 205, 375–381.Google Scholar
Lesage, T., Verrier, C., Bazin, P., Saussey, J. & Daturi, M. (2003). Phys. Chem. Chem. Phys. 5, 4435–4440.Google Scholar
Lima, F. A., Milne, C. J., Amarasinghe, D. C. V., Rittmann-Frank, M. H., van der Veen, R. M., Reinhard, M., Pham, V. T., Karlsson, S., Johnson, S. L., Grolimund, D., Borca, C., Huthwelker, T., Janousch, M., van Mourik, F., Abela, R. & Chergui, M. (2011). Rev. Sci. Instrum. 82, 063111.Google Scholar
Liu, Y., Meirer, F., Krest, C. M., Webb, S. & Weckhuysen, B. M. (2016). Nat. Commun. 7, 12634.Google Scholar
Liu, Y., Meirer, F., Williams, P. A., Wang, J., Andrews, J. C. & Pianetta, P. (2012). J. Synchrotron Rad. 19, 281–287.Google Scholar
Lomachenko, K. A., Borfecchia, E., Negri, C., Berlier, G., Lamberti, C., Beato, P., Falsig, H. & Bordiga, S. (2016). J. Am. Chem. Soc. 138, 12025–12028.Google Scholar
March, A. M., Stickrath, A., Doumy, G., Kanter, E. P., Krässig, B., Southworth, S. H., Attenkofer, K., Kurtz, C. A., Chen, L. X. & Young, L. (2011). Rev. Sci. Instrum. 82, 073110.Google Scholar
Martinez-Criado, G., Borfecchia, E., Mino, L. & Lamberti, C. (2013). Characterization of Semiconductor Heterostructures and Nanostructures II, edited by C. Lamberti & G. Agostini, pp. 361–412. Amsterdam: Elsevier.Google Scholar
Mathon, O., Beteva, A., Borrel, J., Bugnazet, D., Gatla, S., Hino, R., Kantor, I., Mairs, T., Munoz, M., Pasternak, S., Perrin, F. & Pascarelli, S. (2015). J. Synchrotron Rad. 22, 1548–1554.Google Scholar
Mathon, O., Kantor, I. & Pascarelli, S. (2016). X-ray Absorption and X-ray Emission Spectroscopy: Theory and Applications, edited by J. A. van Bokhoven & C. Lamberti, pp. 185–212. Chichester: John Wiley & Sons.Google Scholar
Matsushita, T. & Phizackerley, R. P. (1981). Jpn. J. Appl. Phys. 20, 2223–2228.Google Scholar
Meirer, F., Kalirai, S., Morris, D., Soparawalla, S., Liu, Y., Mesu, G., Andrews, J. C. & Weckhuysen, B. M. (2015). Sci. Adv. 1, e1400199.Google Scholar
Meirer, F., Kalirai, S., Weker, J. N., Liu, Y., Andrews, J. C. & Weckhuysen, B. M. (2015). Chem. Commun. 51, 8097–8100.Google Scholar
Meirer, F., Morris, D. T., Kalirai, S., Liu, Y. J., Andrews, J. C. & Weckhuysen, B. M. (2015). J. Am. Chem. Soc. 137, 102–105.Google Scholar
Meitzner, G., Bare, S. R., Parker, D., Woo, H. & Fischer, D. A. (1998). Rev. Sci. Instrum. 69, 2618–2621.Google Scholar
Meneau, F., Sankar, G., Morgante, N., Winter, R., Catlow, C. R. A., Greaves, G. N. & Thomas, J. M. (2003). Faraday Discuss. 122, 203–210.Google Scholar
Meunier, F. C. (2010). Chem. Soc. Rev. 39, 4602–4614.Google Scholar
Milne, C. J., Penfold, T. J. & Chergui, M. (2014). Coord. Chem. Rev. 277–278, 44–68.Google Scholar
Mino, L., Borfecchia, E., Segura-Ruiz, J., Giannini, C., Martinez-Criado, G. & Lamberti, C. (2018). Rev. Mod. Phys. 90, 025007.Google Scholar
Muddada, N. B., Olsbye, U., Caccialupi, L., Cavani, F., Leofanti, G., Gianolio, D., Bordiga, S. & Lamberti, C. (2010). Phys. Chem. Chem. Phys. 12, 5605–5618.Google Scholar
Muddada, N. B., Olsbye, U., Leofanti, G., Gianolio, D., Bonino, F., Bordiga, S., Fuglerud, T., Vidotto, S., Marsella, A. & Lamberti, C. (2010). Dalton Trans. 39, 8437–8449.Google Scholar
Müller, O., Lützenkirchen-Hecht, D. & Frahm, R. (2015). Rev. Sci. Instrum. 86, 093905.Google Scholar
Müller, O., Nachtegaal, M., Just, J., Lützenkirchen-Hecht, D. & Frahm, R. (2016). J. Synchrotron Rad. 23, 260–266.Google Scholar
Nachtegaal, M., Müller, O., König, C. & Frahm, R. (2016). X-ray Absorption and X-ray Emission Spectroscopy: Theory and Applications, edited by J. A. van Bokhoven & C. Lamberti, pp. 155–183. Chichester: John Wiley & Sons.Google Scholar
Nagai, Y., Dohmae, K., Ikeda, Y., Takagi, N., Tanabe, T., Hara, N., Guilera, G., Pascarelli, S., Newton, M. A., Kuno, O., Jiang, H. Y., Shinjoh, H. & Matsumoto, S. (2008). Angew. Chem. Int. Ed. 47, 9303–9306.Google Scholar
Newton, M. A., Brazier, J. B., Barreiro, E. M., Parry, S., Emmerich, H., Adrio, L. A., Mulligan, C. J., Hellgardt, K. & Hii, K. K. (2016). Green Chem. 18, 406–411.Google Scholar
Newton, M. A., Dent, A. J., Diaz-Moreno, S., Fiddy, S. G., Jyoti, B. & Evans, J. (2003). Chem. Commun. 2003, 1906–1907.Google Scholar
Newton, M. A., Dent, A. J. & Evans, J. (2002). Chem. Soc. Rev. 31, 83–95.Google Scholar
Newton, M. A., Jyoti, B., Dent, A. J., Fiddy, S. G. & Evans, J. (2004). Chem. Commun. 2004, 2382–2383.Google Scholar
Newton, M. A. & van Beek, W. (2010). Chem. Soc. Rev. 39, 4845–4863.Google Scholar
Nikitenko, S., Beale, A. M., van der Eerden, A. M. J., Jacques, S. D. M., Leynaud, O., O'Brien, M. G., Detollenaere, D., Kaptein, R., Weckhuysen, B. M. & Bras, W. (2008). J. Synchrotron Rad. 15, 632–640.Google Scholar
Oyanagi, H., Matsushita, T., Kaminaga, U. & Hashimoto, H. (1986). J. Phys. Colloq. 47, C8-139–C8-142.Google Scholar
Oyanagi, H., Sun, Z. H., Jiang, Y., Uehara, M., Nakamura, H., Yamashita, K., Zhang, L., Lee, C., Fukano, A. & Maeda, H. (2011). J. Synchrotron Rad. 18, 272–279.Google Scholar
Paolucci, C., Parekh, A. A., Khurana, I., Di Iorio, J. R., Li, H., Albarracin Caballero, J. D., Shih, A. J., Anggara, T., Delgass, W. N., Miller, J. T., Ribeiro, F. H., Gounder, R. & Schneider, W. F. (2016). J. Am. Chem. Soc. 138, 6028–6048.Google Scholar
Pascarelli, S., Mathon, O., Mairs, T., Kantor, I., Agostini, G., Strohm, C., Pasternak, S., Perrin, F., Berruyer, G., Chappelet, P., Clavel, C. & Dominguez, M. C. (2016). J. Synchrotron Rad. 23, 353–368.Google Scholar
Pascarelli, S., Neisius, T. & De Panfilis, S. (1999). J. Synchrotron Rad. 6, 1044–1050.Google Scholar
Patlolla, A., Carino, E. V., Ehrlich, S. N., Stavitski, E. & Frenkel, A. I. (2012). ACS Catal. 2, 2216–2223.Google Scholar
Pellegrini, R., Agostini, G., Groppo, E., Piovano, A., Leofanti, G. & Lamberti, C. (2011). J. Catal. 280, 150–160.Google Scholar
Phizackerley, R. P., Rek, Z. U., Stephenson, G. B., Conradson, S. D., Hodgson, K. O., Matsushita, T. & Oyanagi, H. (1983). J. Appl. Cryst. 16, 220–232.Google Scholar
Poo-arporn, Y., Chirawatkul, P., Saengsui, W., Chotiwan, S., Kityakarn, S., Klinkhieo, S., Hormes, J. & Songsiriritthigul, P. (2012). J. Synchrotron Rad. 19, 937–943.Google Scholar
Prestipino, C., Mathon, O., Hino, R., Beteva, A. & Pascarelli, S. (2011). J. Synchrotron Rad. 18, 176–182.Google Scholar
Price, S. W. T., Geraki, K., Ignatyev, K., Witte, P. T., Beale, A. M. & Mosselmans, J. F. W. (2015). Angew. Chem. Int. Ed. 54, 9886–9889.Google Scholar
Price, S. W. T., Ignatyev, K., Geraki, K., Basham, M., Filik, J., Vo, N. T., Witte, P. T., Beale, A. M. & Mosselmans, J. F. W. (2015). Phys. Chem. Chem. Phys. 17, 521–529.Google Scholar
Rabeah, J., Radnik, J., Briois, V., Maschmeyer, D., Stochniol, G., Peitz, S., Reeker, H., La Fontaine, C. & Brückner, A. (2016). ACS Catal. 6, 8224–8228.Google Scholar
Richwin, M., Zaeper, R., Lützenkirchen-Hecht, D. & Frahm, R. (2001). J. Synchrotron Rad. 8, 354–356.Google Scholar
Ruffoni, M. P. & Pettifer, R. F. (2006). J. Synchrotron Rad. 13, 489–493.Google Scholar
Saigo, S., Oyanagi, H., Matsushita, T., Hashimoto, H., Yoshida, N., Fujimoto, M. & Nagamura, T. (1986). J. Phys. Colloq. 47, C8-555–C8-561.Google Scholar
Sankar, G., Cao, E. H. & Gavriilidis, A. (2007). Catal. Today, 125, 24–28.Google Scholar
Sato, T., Nozawa, S., Ichiyanagi, K., Tomita, A., Chollet, M., Ichikawa, H., Fujii, H., Adachi, S. & Koshihara, S. (2009). J. Synchrotron Rad. 16, 110–115.Google Scholar
Smit, E. de, Swart, I., Creemer, J. F., Hoveling, G. H., Gilles, M. K., Tyliszczak, T., Kooyman, P. J., Zandbergen, H. W., Morin, C., Weckhuysen, B. M. & de Groot, F. M. F. (2008). Nature, 456, 222–225.Google Scholar
Smolentsev, G., Guda, A., Zhang, X. Y., Haldrup, K., Andreiadis, E. S., Chavarot-Kerlidou, M., Canton, S. E., Nachtegaal, M., Artero, V. & Sundstrom, V. (2013). J. Phys. Chem. C, 117, 17367–17375.Google Scholar
Smolentsev, G., Guilera, G., Tromp, M., Pascarelli, S. & Soldatov, A. V. (2009). J. Chem. Phys. 130, 174508.Google Scholar
Somorjai, G. A., Beaumont, S. K. & Alayoglu, S. (2011). Angew. Chem. Int. Ed. 50, 10116–10129.Google Scholar
Suzuki, Y. & Terada, Y. (2016). X-ray Absorption and X-ray Emission Spectroscopy: Theory and Applications, edited by J. A. van Bokhoven & C. Lamberti, pp. 251–279. Chichester: John Wiley & Sons.Google Scholar
Tada, M., Ishiguro, N., Uruga, T., Tanida, H., Terada, Y., Nagamatsu, S., Iwasawa, Y. & Ohkoshi, S. (2011). Phys. Chem. Chem. Phys. 13, 14910–14913.Google Scholar
Tada, M., Murata, S., Asakoka, T., Hiroshima, K., Okumura, K., Tanida, H., Uruga, T., Nakanishi, H., Matsumoto, S., Inada, Y., Nomura, M. & Iwasawa, Y. (2007). Angew. Chem. Int. Ed. 46, 4310–4315.Google Scholar
Tamenori, Y. (2013). J. Synchrotron Rad. 20, 419–425.Google Scholar
Terada, Y., Tanida, H., Uruga, T., Takeuchi, A., Suzuki, Y., Goto, S., McNulty, I., Eyberger, C. & Lai, B. (2011). AIP Conf. Proc. 1365, 172–175.Google Scholar
Thomas, J. M. (1997). Chem. Eur. J. 3, 1557–1562.Google Scholar
Tibiletti, D., Amieiro-Fonseca, A., Burch, R., Chen, Y., Fisher, J. M., Goguet, A., Hardacre, C., Hu, P. & Thompsett, A. (2005). J. Phys. Chem. B, 109, 22553–22559.Google Scholar
Toyoshima, R. & Kondoh, H. (2015). J. Phys. Condens. Matter, 27, 083003.Google Scholar
Uruga, T., Tanida, H., Inoue, K., Yamazaki, H. & Irie, T. (2007). AIP Conf. Proc. 882, 914–916.Google Scholar
Valenzano, L., Vitillo, J. G., Chavan, S., Civalleri, B., Bonino, F., Bordiga, S. & Lamberti, C. (2012). Catal. Today, 182, 67–79.Google Scholar
Xu, M. J., Tang, Z. T., Duan, Y. X. & Liu, Y. (2016). Crit. Rev. Anal. Chem. 46, 291–304.Google Scholar
Yao, S. Y., Mudiyanselage, K., Xu, W. Q., Johnston-Peck, A. C., Hanson, J. C., Wu, T. P., Stacchiola, D., Rodriguez, J. A., Zhao, H. Y., Beyer, K. A., Chapman, K. W., Chupas, P. J., Martínez-Arias, A., Si, R., Bolin, T. B., Liu, W. J. & Senanayake, S. D. (2014). ACS Catal. 4, 1650–1661.Google Scholar